1. bypass-type load control
It shows the solar panel recharges the photoperiod through the diode directly to the lithium-ion battery charging, the battery for each battery charging circuit branch is established. When a single cell voltage reach the set value, the load circuit bypass began to turn the power transistor, the shunt part of the load current to maintain voltage single cell of a constant in a very narrow range. The nature of the charge current gradually reduces VGP-BPS10 battery (approximately exponentially) until the end of illumination. This pricing method can guarantee that every single cell balance charging, but the dissipation branch circuit power over the load current is difficult to measure.
2. Shunt type charge control
Single cell by checking the battery voltage different sampling circuit, respectively, after, or remove a single cell gate voltage is maximum in the conversion circuit signal from the reference signal generated error signal, the signal error in the shunt regulator circuit to control the lithium-ion battery voltage in the monomer. Either the battery voltage reaches a given value, the battery charge current decreases on average. Using a switching regulator shunt, then the only constant voltage charging, the charging current is exciting, so using this control method requires the lithium-ion rechargeable battery capable of adapting to the pulse load current.
The main error amplifier (MEA) of the sample signal bus voltage to generate the error signal sent to the shunt regulator. In other words, the shunt regulator is also covered by a single VGP-BPS13 battery voltage and bus voltage control of the battery.
3. Sub-type load control
Comparison of single cell by the inspection sampling a single cell voltage of the circuit, any voltage single cell exceeds a given value, or it will produce a more door-voltage signal, the circuit unplug all the way through the load lock forward, decreasing the load current 1 / 3, when once again produced an over-voltage signal to turn the table second charge, until the last off the table load. At the advent of pulsed load or enter periods shadow of the earth, generate unlock signal to unlock the circuit makes charging control circuit for the next charging process. Obviously, when the constant voltage, the load current is exponentially related, but the level ladder-type decline. Sub-type lithium-ion charging circuit of battery control shown in Figure 3.
4. single-peak voltage stress of the VGP-BPS11 battery control linear
Single cell have been sampled by the voltage circuit inspection of each single cell, after, or delete a single voltage gate cell of maximum, after the conversion circuit in the signal control circuit voltage limits, voltage review the limits of management power circuits dynamically adjusting the impedance control of lithium-ion battery cell voltage of the single. When either a single cell voltage reaches or highlighted, the solar panel to a substantially stable in the current limiting circuit voltage control in power management of lithium-ion battery load impedance tube Electric is close to zero when any Only a voltage single cell reaches the configured value, the impedance of the power tube has gradually increased the load current of the battery gradually decreases, the load current decreases by laws of the characteristics of lithium-ion batteries decision (approximately exponentially). This circuit has the advantage of the phase constant voltage load decreases, load current, essentially exponentially, compared to adapt lithium-ion battery charging habits, the charging circuit power consumption not much